UL-142 StandardHome

UL-142 STANDARD SYSTEM DESCRIPTIONUnderwriters Laboratories Logo
SuperSafe's Inherent Prevention by Design. The SuperSafe Tank Overfill Protection System employs six redundant safety features in its design and assembly. These standard features include:

  • A large-faced volume gauge calibrated in feet and inches to demonstrate the available The SuperSafe Tank Overfill Protection Systemremaining capacity within the primary tank.
  • A weather-tight sticking hatch on top of the Cylindrical Dike so that the manual fuel level determination can be made (required per API).
  • A fail-safe high-level alarm, not dependent on the volume gauge, that will sound an alarm, flash a beacon and stop the pump motor, Per: NFPA-30 2-10.1b.
  • A fail-safe high-level hydraulic valve built to ANSI B16.5 Standard and meets NFPA-30 2-10.1.1 Emergency independent shutdown system.
  • Emergency overflow vent directly funneling fuel into the annular interstitial space which has a 25% greater capacity than the primary tank.
  • Annular Interstitial liquid sensor to recognize a nonstandard condition and sound an alarm, flash a beacon and stop the pump motor.

The SuperSafe Spill Protection System is composed of:

  • Kamlock and dry-break couplers.
  • Filling adapters installed at an elevated 45 degree angle so that even the smallest drop isn't lost during hose disconnect.
  • Spring loaded full port inlet check valve ensure prevention of reverse flow.
  • A slow-closing hydraulic high-level shutdown valve prevents hydraulic shock to up-stream components.
  • Tank sumping and product supply pipingDispensing or suction piping that is configured utilizing down-stream components of solenoid valves, fire-link valves and shear valves as appropriate.
  • Tank sumping and product supply piping are protected from fuel siphoning with the SuperSafe Antisipon System.
  • All fill, suction, dispensing and vapor recovery piping is secondarily contained in weather-tight, liquid-tight compartment with monitoring ports or liquid detecting sensors where necessary.

The SuperSafe Spill Protection System

The SuperSafe Leak Protection System:

  • Ensures that in the unlikely event of a tank leak, the escaping product would be captured within the Cylindrical Dike. A fail-safe engineered self diagnostic liquid sensor in the dike sump will recognize the non- standard condition and sound an alarm.
  • Features piping that is integral and or fully contained within the weather- tight pumping compartment. The liquid-tight secondary containment capacity is twice the sum of the liquid bearing components' volumetric capacity.

The SuperSafe Vandalism Protection System is a design of prevention.

  • All access to the stored product is lockable - fill and pump compartment doors, all pipe adapter caps, inspection and sticking hatches.
  • Threaded or bolted access is torqued to the maximum allowable - volumetric gauge, bolted ingress manhole, exposed electrical junction boxes, emergency and working vents.

[CONTINUE TO PAGE 3]

   
 